![]() Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.įigure 607.4.1 Grab Bars for Bathtubs with Permanent Seats Bathtubs Without Permanent Seatsīack Wall. Each grab bar shall be installed 15 inches (380 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall.Ĭontrol End Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub. Grab Bars in Tub Requirements Bathtubs With Permanent Seatsīack Wall. A folding seat shall be provided in roll-in type showers required in transient lodging guest rooms with mobility features complying with 806.2. A folding or non-folding seat shall be provided in transfer type shower compartments. ![]() Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls.įigure 608.3.3 Grab Bars for Alternate Roll-In Type ShowersĦ08.4 Seats. Grab bars shall not be provided above the seat. Transfer Type Shower Compartments - In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.įigure 608.3.2 Grab Bars for Standard Roll-In Type ShowersĪlternate Roll-In Type Shower Compartments - In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 608.3. Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 608.3.Ģ. Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor.ġ. A 36 inch (915 mm) wide minimum entry shall be provided at one end of the long side of the compartment.Ħ08.3 Grab Bars - Grab bars shall comply with 609 and shall be provided in accordance with 608.3. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment.ĮXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls or, where provided, not on the side of the clearance adjacent to the shower seat.Īlternate Roll-In Type Shower Compartments - Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides. Standard Roll-In Type Shower Compartments - Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry on the face of the shower compartment.Ħ08.2.2.1 Clearance. ![]() Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided. Transfer Type Shower Compartments - Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915 mm) wide minimum entry on the face of the shower compartment. The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the location of a recessed fixture adjacent to the water closet. Rear Wall - The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on the other side.ĮXCEPTIONS: 1. Side Wall - The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ADA Grab Bar Requirements for Shower Stalls, Bath Tubs, and Toilet StallsĬONSULT MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR PROPER INSTALLATION OF SPECIFIC PRODUCT.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |